  • 数据冗余信息引导的低剂量心肌灌注CT成像方法

    Subjects: Medicine, Pharmacy >> Preclinical Medicine submitted time 2018-06-15 Cooperative journals: 《南方医科大学学报》

    Abstract: Objective In the clinic, myocardial perfusion computed tomography (MPCT) imaging is commonly used to detect and assess myocardial ischemia quantitatively. However, repeated scanning on the myocardial region in the cine mode will increase the radiation dose for patients. With lowering radiation dose, the quality of images are degraded by noise induced artifact, which hampers the diagnostic accuracy. Therefore, in this paper, we propose a redundancy information induced iterative reconstruction framework for high quality MPCT images at the case of low dose. Methods MPCT images have redundant structural information within frames and highly similarity between adjacent frames. Inspired by the two properties, in this work we propose a penalized weighted least-squares (PWLS) model incorporating NLM and TV based hybrid constraints, which is referred to as PWLS-aviNLM-TV for simplicity. The proposed algorithm can effectively eliminate noise and artifacts by taking into account the similarity between adjacent frames and redundancy information within frames, which also can improve spatial resolution within frames and maintain temporal resolution. Results The experimental results on the 4D extended cardiac-torso (XCAT) phantom and preclinical porcine dataset demonstrates that the PWLS-aviNLM-TV algorithm obtains better performance in terms of noise reduction and artifacts suppression than the PWLS-TV and PWLSaviNLM algorithm. Moreover, the proposed algorithm can preserve the edges and detail information thereby efficiently differentiate ischemia from myocardium. Conclusion The present redundancy information induced reconstruction algorithm can reconstruct high-quality images from low-dose MPCT for better clinical imaging diagnosis.

  • 基于运动补偿的压缩感知4D-CBCT优质重建

    Subjects: Medicine, Pharmacy >> Preclinical Medicine submitted time 2017-12-27 Cooperative journals: 《南方医科大学学报》

    Abstract: Restriction by hardware caused the very low projection number at a single phase for 4-dimensional cone beam (4D-CBCT) CT imaging, and reconstruction using conventional reconstruction algorithms is thus constrained by serious streak artifacts and noises. To address this problem, we propose an approach to reconstructing 4D-CBCT images with multi-phase projections based on the assumption that the image at one phase can be viewed as the motion-compensated image at another phase. Specifically, we formulated a cost function using multi-phase projections to construct the fidelity term and the TV regularization method. For fidelity term construction, the projection data of the current phase and those at other phases were jointly used by reformulating the imaging model. The Gradient-Projection-Barzilai-Line search (GPBL) method was used to optimize the complex cost function. Physical phantom and patient data results showed that the proposed approach could effectively reduce the noise and artifacts, and the introduction of additional temporal correlation did not introduce new artifacts or motion blur.

  • 基于投影域小波滤波处理的CT图像环形伪影去除方法

    Subjects: Medicine, Pharmacy >> Preclinical Medicine submitted time 2017-12-07 Cooperative journals: 《南方医科大学学报》

    Abstract: Objective Ring artifacts often appear in flat-panel detector-based CT images due to the malfunction or mis-calibration of the detector elements that result in stripe artifacts in the line integral projection (sinogram) data. The ring artifacts lower the image quality and affect image-based diagnoses. Here we propose a ring artifacts removal approach based on wavelet filtering in the sinogram domain. The line integral projection (sinogram) dataset were divided into 4 sub-sinogram dataset, and for each of them the wavelet decomposition operation was employed to produce the associated wavelet dataset, followed by filtering operation on the vertical detail band and the low-pass detail band. Wavelet reconstruction operation was then performed, and the weighted moving average filter was used to yield the filtered sinogram, which was processed using filtered back-projection (FBP) for image reconstruction. The results showed that the proposed approach could effectively remove the ring artifacts while preserving the structural information of the image.