分类: 核科学技术 >> 粒子加速器 提交时间: 2023-06-18 合作期刊: 《Nuclear Science and Techniques》
摘要: In building Shanghai Synchrotron Radiation Facility (SSRF), in order to reduce or eliminate the unnecessary sources of beam motion, the precise and stable beam position measurement system in the feedback system was required. In this study, we focused on theoretical analysis of the electrode of beam position monitor (BPM). Simulations, including analytic derivations of the propagation impedance and the distribution inductance, were performed. The BPM was designed based on the results and the acceptance measurements of the impedance and the inductance by using the time domain reflection (TDR) with a network analyzer. It has been proved in years of operations that the BPM system meets the requirement of the resolution of sub-micron.
分类: 核科学技术 >> 粒子加速器 提交时间: 2023-06-18 合作期刊: 《Nuclear Science and Techniques》
摘要: Beam position monitors (BPMs) have been widely used in all kinds of measurement systems, feedback systems and other areas in particle accelerator field these days. The malfunction of a single BPM can cause serious consequences such as the failure of the orbit feedback and the transverse feedback. A troubleshooting has been made to prevent the defective BPMs from affecting the accuracy and stability of the storage ring in Shanghai Synchrotron Radiation Facility (SSRF). Different types of malfunctions have been successfully identified by using the idea of principal component analysis (PCA).