Subjects: Physics >> Nuclear Physics submitted time 2024-02-09
Abstract: An ultrafast framing camera with a pulse-dilation device, a microchannel plate (MCP) imager, and an electronic imaging system were reported. The camera achieved a temporal resolution of 10 ps by using a pulse-dilation device and gated MCP imager, and a spatial resolution of 100 μm by using an electronic imaging system comprising combined magnetic lenses. The spatial resolution characteristics of the camera were studied both theoretically and experimentally. The results showed that the camera with combined magnetic lenses reduced the field curvature and acquired a larger working area. A working area with a diameter of 53 mm was created by applying four magnetic lenses to the camera. Furthermore, the camera was used to detect the X-rays produced by the laser-targeting device. The diagnostic results indicated that the width of the X-ray pulse was approximately 18 ps.
Subjects: Nuclear Science and Technology >> Nuclear Detection Technology and Nuclear Electronics submitted time 2022-05-20
Abstract:
"
Peer Review Status:Awaiting Review