分类: 核科学技术 >> 粒子加速器 提交时间: 2023-06-18 合作期刊: 《Nuclear Science and Techniques》
摘要: Particle induced X-ray Emission (PIXE) was used to analyze the proto-porcelain excavated from Tingziqiao kiln site of Warring States (475221 BC) in Deqing County of Zhejiang Province, China. It was found that the porcelain body and glaze differ from each other in recipes. The porcelain clay of high silicon and low aluminum might be used to make the body of proto-porcelain. Lime and plant or wood ashes might be added into the glaze of the proto-porcelain. Cluster analysis was done to reveal the compositional relationship between the proto-porcelain samples.
分类: 核科学技术 >> 裂变堆工程技术 提交时间: 2023-06-18 合作期刊: 《Nuclear Science and Techniques》
摘要: In the nuclear reactor design, a code for automatically generated multi-temperature continuous-energy neutron cross section data library, which is called AMTND for short, was designed and developed to meet the need of the reactor core design coupled with thermal-hydraulic design. The code can provide a point-wise cross-section at any temperature for a Monte Carlo neutron transport program, such as MCNP. In ensuring that the nuclear data produced by AMTND meets the testing of critical benchmark experiments, the time-consumed by the nuclear data generating of AMTND compared with NJOYs was carried out and the result shows the codes excellence. In order to test the accuracy of the code, the Doppler coefficient test benchmark was also carried out and the results verified the code preliminarily.
分类: 物理学 >> 核物理学 提交时间: 2023-07-06
摘要: Proton computed tomography (CT) has a distinct practical significance in clinical applications. It eliminates 35% errors caused by the transformation of Hounsfield unit (HU) to relative stopping power (RSP) valueswhen using X-ray CT for positioning andtreatment planning systems (TPSs). Following the development of FLASH proton therapy, there are increased requirements for accurate and rapid positioning in TPSs. Thus, anewrapid proton CT imaging mode is proposed based on sparsely sampled projections. The proton beam wasboosted to 350 MeV by a compact proton linear accelerator (linac). In this study,thecomparisons of the proton scattering with the energyof 350 MeV and 230 MeV are conducted based on GEANT4simulations.Asthe sparsely sampledinformation associated with beam acquisitions at 12angles is not enough for reconstruction, X-ray CT is used as a prior image. The RSP map generated by converting the X-ray CT was constructed based onMonte Carlo simulations. Consideringtheestimationof the most likely path (MLP), the prior image-constrained compressed sensing (PICCS) algorithm isused to reconstruct images from twodifferent phantoms using sparse protonprojections of 350 MeV parallel proton beam. The results show that it is feasible to realize the proton image reconstruction with the rapid protonCT imaging proposed in this paper. It can produce RSP maps withmuchhigher accuracy for TPSs and fast positioning to achieve ultra-fast imaging for real-time image-guided radiotherapy(IGRT) in clinical proton therapyapplications.